Thoratec HeartMate II LVAS

Thoratec HeartMate II LVAS
  images courtesy Thoratec Corporation, Inc.

The Thoratec HeartMate® II LVAS was developed  and tested by Thoratec Corporation, Inc., and the Texas Heart Institute (THI). The HeartMate II is being evaluated initially for use as a bridge to transplantation. Eventually, it is hoped that the HeartMate II can be used for destination therapy—as permanent support for end-stage heart failure patients who are not eligible for heart transplantation.

April 24, 2008 News Release

HeartMate II Approved as Advanced-Stage Heart Failure Treatment Option
THI plays a significant role in clinical studies leading to FDA approval of left-ventricular assist device as a bridge-to-transplantation therapy.

The Pump

The HeartMate II is a high-speed, axial flow, rotary blood pump. As an axial flow device, the  HeartMate II produces no pulsatile action. Weighing 12 ounces (about 375 grams) and measuring about 1.5 inches (4 cm) in diameter and 2.5 inches (6 cm) long, it is significantly smaller than other currently approved devices. As such, it may be suitable for a wider range of patients, including small adults and children.

Thoratec HeartMate II LVAS
The internal pump surfaces are a smooth, polished titanium. Within the pump is a rotor that contains a magnet. The rotor assembly is rotated  by the electromotive force generated by the motor. The rotor propels the blood from the inflow cannula out to the natural circulation. The pump speed can vary from 6,000 rpm to 15,000 rpm, providing blood flow of up to 10 liters per minute.

The pump can run in two operating modes: fixed speed and auto-speed. In fixed-speed mode, the device operates at a constant speed, which can be adjusted via the system monitor. In the auto-speed mode, the pump speed varies in response to different levels of patient or cardiac activity.

External Equipment

External equipment includes a system driver, a power base unit, and a 20-foot power cable, as well as batteries and other accessories. The system driver continuously monitors and controls the implanted motor and shows information regarding alarm conditions.

The power base unit serves as a battery charger and an interface between the system monitor  and the implanted pump. The 20-foot power cable allows the system to be operated by AC power. Patients can wear a portable battery pack around their waist, which permits the system to be operated tether-free for 3 hours.

Updated April 2008

Top  
This website is accredited by Health On the Net Foundation. Click to verify. We comply with the HONcode standard for trustworthy health information:
Verify here.

Please contact our Webmaster with questions or comments.
Terms of Use and Privacy Policy
© Copyright 1996-2008 Texas Heart Institute. All rights reserved.
Texas Heart Institute, Texas Heart, Texas Heart Institute Journal, THI, Heart Owner's, Leading With the Heart and Heart of Discovery are members of the
family of trademarks of the Texas Heart Institute.
USNews and World Report America's Best Hospitals - 2008